Changes in the consumption of blood glucose test strips among patients in Germany who use FGM systems
Prof. Dr. re. medical habil. Karel Kostev MA / Dr. med. Louisa van den Boom
In Germany, around 7.5 million people live with diabetes (IDF2017) [1]. A total of 95% of them have type 2 diabetes (T2D) and 5% have diabetes type 1 (T1D) or another type according to the diabetes classification [2]. In many cases, oral antidiabetic drugs for T2D or insulin for T1D and T2D can be used very successfully [3-4]. The goal of diabetes management is always to achieve and maintain good blood sugar control. As recommended by the American Diabetes Association, a glucose level of 70-180 mg/dl (3.8-10 mmol/l) should be achieved. This value can of course be adjusted individually as required. The second goal is to avoid hypoglycemia (<70 mg/dl or <3.8 mmol/l) and hyperglycemia (>180 mg/dl or 10 mmol/l) as much as possible. The long-term goal of diabetes treatment is the prevention of diabetes complications such as retinopathy, nephropathy and neuropathy [5-10]. The biggest burden in the daily life of a patient with diabetes is monitoring blood sugar. Many fingertip blood samples are necessary every day in order to be able to adjust the individual insulin regimen and achieve good blood sugar control. In order to achieve optimal blood sugar control with intensive therapy, frequent blood sugar measurements are necessary (self-monitoring of blood sugar levels (SMBG)). Unfortunately, capillary blood sampling is not able to adequately prevent hypoglycemia and hyperglycemia. Hypoglycemia and hyperglycemia affect quality of life, and hypoglycemia in particular is a major burden in living with diabetes [11]. Blood glucose testing is very time-consuming and painful and many factors must be taken into account. In addition, capillary blood glucose measurements only represent a snapshot of the current glucose level. Flash Glucose Monitoring (FGM) has been available in Germany since 2014 and is reimbursed by health insurance companies for adults and children aged 4 and over with T1D and T2D.
Read more
First publication date: 28.07.2020
Downloads
Abstract: Veränderungen im Verbrauch von Blutzuckerteststreifen bei Patienten in Deutschland, die FGM-Systeme anwenden
Since 2014, FGM (Flash Glucose Monitoring) measurement systems have been available to patients with type 1 diabetes (T1D) and type 2 diabetes (T2D). FGM is a bloodless, painless and very simple method of monitoring patients' glucose levels. The aim of this study was to compare the daily consumption of blood glucose test strips (BZTS) before and after the start of FGM use. This study included 1,343 adult (≥18 years) T1D and T2D patients (mean age 51.4 years; 39, 1% women) from the Disease Analyzer database (IQVIA) with an initial prescription for an FGM system issued in Germany between January 2015 and July 2018 (index date). The average daily BZTS consumption before and the average daily BZTS consumption after the index date were compared. A multivariate logistic regression model was used to examine the association between predefined variables and the likelihood of BZTS discontinuation after the index date. The average daily BZTS consumption per patient decreased from 2.7 (SD: 3.0) before the index date to 1.4 (SD: 2.4) after the index date and was similar in male and female T1D and T2D patients in different age groups and in diabetology practices and general practices. Overall, 40% of patients continued to use BZTS, and 30% used BZTS at least once daily. Male gender and HbA1c <6.5% and less frequent use of BZTS before the index date were positively associated with non-use of BZTS after the index date.
Abstract: Changes in the consumption of blood glucose test strips in patients in Germany who use FGM systems
ince 2014, Flash glucose monitoring (FGM) systems have been available for patients with type 1 (T1D) and type 2 (T1D) diabetes. FGM is a bloodless, painless, and very easy method to monitor patients' glucose values. The aim of this study was to compare the daily consumption of blood glucose test strips (BGTS) before and after the initiation of FGM use.This study included 1,343 adult (≥18 years) T1D and T2D patients (mean age 51.4 years; 39.11 TP3T women) from the Disease Analyzer database (IQVIA) with an initial prescription of FGM in Germany between January 2015 and July 2018 (index date). A comparison of the average BGTS daily consumption after the index date versus prior to the index date was made. A multivariate logistic regression model was used to investigate the association between predefined variables and the probability of no longer using BGTS after the index date.The average daily BGTS consumption per patient decreased from 2.7 (SD: 3.0) prior to the index date to 1.4 ( SD: 2.4) after the index date and was similar in T1D and T2D, in both women and men, and across different age groups, as well as in diabetologist practices and general practices. In total, 40% of patients continued to use BGTS, and 30% used them at least once daily. Male sex and HbA1c <6.5%, as well as less frequent use of BGTS prior to the index date, were positively associated with non-use of BGTS after the index date.
Keywords (English)
Literature
1. Cho NH, Shaw JE, Karuranga S, Huang Y, da Rocha Fernandes JD, Ohlrogge AW, Malanda B. IDF Diabetes Atlas: Global estimates of diabetes prevalence for 2017 and projections for 2045. Diabetes Res Clin Pract. 2018 Apr;138:271-281. doi: 10.1016/j.diabres.2018.02.023. Epub 2018 Feb 26. 2. Diagnosis and Classification of Diabetes Mellitus. American Diabetes Association. Diabetes Care 2013 Jan; 36(Supplement 1): S67-S74. https://doi.org/10.2337/dc13-S067. 3. DiMeglio LA, Evans-Molina C, Oram RA. Type 1 diabetes. Lancet. 2018 Jun 16;391(10138):2449-2462. doi: 10.1016/S0140-6736(18)31320-5. 4. Reusch JE, Manson JE. Management of Type 2 Diabetes in 2017: Getting to Goal. JAMA. 2017 Mar 14;317(10):1015-1016. doi: 10.1001/jama.2017.0241. 5. Wright LA, Hirsch IB. Metrics Beyond Hemoglobin A1C in Diabetes Management: Time in Range, Hypoglycemia, and Other Parameters. Diabetes Technol Ther. 2017 May;19(S2):S16-S26. doi: 10.1089/dia.2017.0029. 6. BattelinoT, DanneT, Bergenstal RM, Amiel SA, Beck R, Biester T, Bosi E et al.. Clinical Targets for Continuous Glucose Monitoring Data Interpretation: Recommendations From the International Consensus on Time in Range. Diabetes Care 2019 Aug; 42(8): 1593-1603. https://doi.org/10.2337/dci19-0028. 7. Hirsch IB, Sherr JL and Hood KK. Connecting the Dots: Validation of Time in Range Metrics With Microvascular Outcomes. Diabetes Care 2019 Mar; 42(3): 345-348. https://doi.org/10.2337/dci18-0040. 8. Beck RW, Bergenstal RM, Riddlesworth TD, Kollman C, Li Z, Brown AS and Close KL. Validation of Time in Range as an Outcome Measure for Diabetes Clinical Trials. Diabetes Care 2019 Mar; 42(3): 400-405. https://doi.org/10.2337/dc18-1444. 9. Diabetes Control and Complications Trial Research Group, Nathan DM, Genuth S, Lachin J, Cleary P, Crofford O, Davis M, Rand L, Siebert C. The effect of intensive treatment of diabetes on the development and progression of long-term Complications in insulin-dependent diabetes mellitus. N Engl J Med 1993 Sep 30;329(14):977-86. 10. Nathan DM; DCCT/EDIC Research Group. The diabetes control and complications trial/epidemiology of diabetes interventions and complications study at 30 years: overview. Diabetes Care. 2014;37(1):9-16. doi: 10.2337/dc13-2112. 11. Bode BW, Schwartz S, Stubbs HA, Block JE. Glycemic characteristics in continuously monitored patients with type 1 and type 2 diabetes: normative values. Diabetes Care 2005;28:2361–2366. 12. Hirsch IB. Professional flash continuous glucose monitoring as a supplement to A1C in primary care. Postgrad Med. 2017 Nov;129(8):781-790. doi: 10.1080/00325481.2017.1383137. Epub 2017 Oct 5. 13. Anjana RM, Kesavadev J, Neeta D, Tiwaskar M, Pradeepa R, Jebarani S ,Thangamani S. A Multicenter Real-Life Study on the Effect of Flash Glucose Monitoring on Glycemic Control in Patients with Type 1 and Type 2 diabetes. Diabetes Technol Ther. 2017 Sep;19(9):533-540. 14. Rathmann W, Bongaerts B, Carius HJ, Kruppert Y, Kostev K. Basic characteristics and representativeness of the German Disease Analyzer Database. Int J Clin Pharmacol Ther. 2018 Oct;56(10):459-466. doi: 10.5414/CP203320. 15. Tyndal V, Stimson RH, Zammitt NN, et al. Marked improvement in HbA1c following commencement of flash glucose monitoring in people with type 1 diabetes. Diabetologia 2019; 62: 1349-1356 doi: 10.1007/s00125-019-4894-1. Epub 2019 Jun 9. 16. Bolinder J, Antuna R, Geelhoed-Duijvestijn P, Kröger J, Weitgasser R. Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomized controlled trial. Lancet. 2016 Nov 5;388(10057):2254-2263. doi: 10.1016/S0140-6736(16)31535-5. Epub 2016 Sep 12. 17. van den Boom L., Karges B, Auzanneau M, Rami-Merhar B, Lilienthal E, von Sengbusch S, Datz N. Temporal Trends and Contemporary Use of Insulin Pump Therapy and Glucose Monitoring Among Children, Adolescents , and Adults with Type 1 Diabetes Between 1995 and 2017. Diabetes Care. 2019 Nov;42(11):2050-2056. doi: 10.2337/dc19-0345. Epub 2019 Sep 5. 18. Szadkowska A. , Gawrecki A, Michalak A, Zozuliska-Ziółkiewicz D, Fendler W, Młynarski W. Flash glucose measurements in children with type 1 diabetes in real-life settings: To trust or not to trust? Diabetes Technol Ther. 2018 Jan;20(1):17-24. doi: 10.1089/dia.2017.0287. Epub 2017 Dec 13. 19. Moser O, Eckstein ML, McCarthy O, Deere R, Pitt J, Williams DM, Hayes J. Performance of the Freestyle Libre flash glucose monitoring (flash GM) system in individuals with type 1 diabetes: A secondary Outcome analysis of a randomized crossover trial. Diabetes Obes Metab. 2019 Nov;21(11):2505-2512. doi: 10.1111/dom.13835. Epub 2019 Aug 5. 20. Aleppo G., Ruedy KJ, Riddlesworth TD, Kruger DF , Peters AL, Hirsch I, Bergenstal RM et al for the REPLACE-BG Study Group.REPLACE-BG: A Randomized Trial Comparing Continuous Glucose Monitoring With and Without Routine Blood Glucose Monitoring in Adults With Well-Controlled Type 1 Diabetes Diabetes Care 2017 Apr; 40(4): 538-545. https://doi.org/10.2337/dc16-2482 21. Tanenbaum ML, Hanes SJ, Miller KM, Naranjo D, Bensen R, Hood KK. Diabetes device use in adults with type 1 diabetes: barriers to uptake and potential intervention targets. Diabetes Care 2017;40:181–187